| Place of Origin |
Guangdong China (Mainland) |
| Brand Name |
KLD |
| Model Number |
SCS-120 |
| Power Supply |
110V+-10%; 220V +-10% AC |
| Display Type |
LED |
| Rated Load |
120 Tons |
| Accuracy |
20Kg |
| Type |
Truck Scale |
120 Tons Electronic ChineseWeighbridge Main technical parameters for IndicatorConversion ModeDouble integral A/DSignal input range-60mv +60mvConversion modeOver 50HzNon-linearity<0.01%F.SPower supplyDC, 15V, 350mADisplay6-bit fluorescent display, 0.8 inches in digit heightDisplay range00000 99995Number of digital key0 9 keysFunction key20 keysTransmission distance≤2000mOperating temperature0 44°CRelative moisture≤90%RHWarm-up time15minFuse20mA Main technical Parameters for bridge-typed load cellTypeweighRated Load10t,20t,30t,40t,50tRated Output2.0000±0.001MV/VTotal Error±0.02%F.SCreep(30minutes)±0.02%F.SRecommended Excitation Voltage5V∼18V(AC or DC)Max. Excitation Voltage24V(AC or DC)Zero Balance±1%F.SInput Impedance775±5ΩOutput Impedance700±2ΩInsulation Impedance≥5000MΩSafe Overload150%F.SUltimate Overload200%F.SOperating Temperature Range(-30∼+70)Compensated Temperature Range(-20∼+60)Temperature Effect On Load±0.02%F.S/10Temperature Effect On Zero±0.02%F.S/10ConstructionAlloy SteelProtection ClassIP68&IP67